Connecting the T1 module (without serial interface) 3-21
Chapter 3: Setting Up the Wave IP 500 Server
Wave Server Installation Guide
Connecting the T1 module (without serial interface)
Note: This section describes how to connect the 1-port T1/PRI module without serial interface.
For information about installing the 1-port T1 module with serial interface, see page 3-20.
The T1 module supports one T1 or ISDN PRI digital trunk.
There are 2 connectors on the T1 module:
The RJ-48C port is used to connect to the T1 or ISDN PRI network interface.
The bantam jack located to the right of the RJ-48C port accepts a 3-conductor Bantam
cable. It is provided for diagnostic purposes and is to be used only by an authorized
technician.
The T1 module is a partial-width module that can be installed in any module slot. This module
has one alarm indicator for the T1 port. See “Alarm indicators” in Chapter 15 in the Wave
Hardware Reference Guide for more information.
To connect the T1 module:
1. Locate the RJ-48C port on the module.
2. Connect the T1 cable to the RJ-48C port.
Release 2.0 Service Pack 1
April 2011